Violation Detail
Standard Cited: 19100217 B07 III Mechanical power presses.
Inspection Nr: 1447344.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,145.00
Current Penalty: $7,800.00
Issuance Date: 05/06/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0317500
Contest Date: 05/29/2020
Final Order: 09/18/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/18/2020 | $7,800.00 | Serious | ||
Penalty | C: Contested | 06/01/2020 | $12,145.00 | Serious | ||
Penalty | Z: Issued | 05/06/2020 | $12,145.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.217(b)(7)(iii): The means of selecting Off, "Inch," Single Stroke, and Continuous (when the continuous function is furnished) that was supplied with the clutch/brake control to select type of operation of the press was not capable of being supervised by the employer: Instances including, but not limited to, the following: a) Job site, 33 McGovern Road, Crescent, PA: On or about November 23, 2019, during production activities on the Torc-Pac part revolution press number 11, serial number 57-7135, located in building 4, the employer did not ensure that the mode control selection switch was supervised so as to prevent selections between different operating modes.