Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1441612.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 04/27/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0627100
Contest Date: 05/22/2020
Final Order: 12/10/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/10/2021 | $0.00 | Serious | ||
Penalty | C: Contested | 05/22/2020 | $13,494.00 | Serious | ||
Penalty | Z: Issued | 04/27/2020 | $13,494.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about October 29, 2019 and times prior thereto, an employee disassembled the Auger on Line #17 in the Pie Room without utilizing a lockout tagout procedure. The employer failed to ensure lockout tagout was utilized.