Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1427264.015
Citation: 01003
Citation Type: Serious
Abatement Date: 03/19/2020 2
Initial Penalty: $13,494.00
Current Penalty: $7,699.96
Issuance Date: 02/25/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0215800
Contest Date: 03/19/2020
Final Order: 11/30/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 11/30/2020 | $7,699.96 | 03/19/2020 | Serious | |
Penalty | C: Contested | 03/20/2020 | $13,494.00 | 03/19/2020 | Serious | |
Penalty | Z: Issued | 02/25/2020 | $13,494.00 | 03/19/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a. At the facility, on or about 9/5/2019: Employees performing maintenance and/or repairs on equipment which could be hazardous during unexpected startup or energization. The employer had not developed equipment specific energy control procedures for equipment including but not limited to washers, dryers, shuttles and linen folders.