Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1427100.015
Citation: 01003
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $11,000.00
Issuance Date: 02/21/2020
Nr Instances: 1
Nr Exposed: 100
Abatement Date: 10/14/2022
Gravity: 10
Report ID: 0214200
Contest Date: 03/13/2020
Final Order: 10/14/2020
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/14/2020 | $11,000.00 | 10/14/2022 | Other | |
Penalty | C: Contested | 03/23/2020 | $13,494.00 | 03/16/2020 | Serious | |
Penalty | Z: Issued | 02/21/2020 | $13,494.00 | 03/16/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Workplace, NJ Route 440 and 22nd Street, Bayonne, NJ a) The employer did not conduct a periodic inspection of their energy control procedure with the last such inspection occurring on November 8, 2016. Employees are required to utilize energy control procedures while performing maintenance and servicing activities to include but not limited to flange slip removal from pipelines. Violation occurred on or about 8-28-19