Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1425507.015
Citation: 01003
Citation Type: Serious
Abatement Status:
Initial Penalty: $11,934.00
Current Penalty: $0.00
Issuance Date: 01/09/2020
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 02/27/2020
Gravity: 10
Report ID: 0522300
Contest Date: 02/05/2020
Final Order: 09/28/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 09/28/2020 | $0.00 | 02/27/2020 | Serious | |
| Penalty | C: Contested | 02/05/2020 | $11,934.00 | 02/27/2020 | Serious | |
| Penalty | Z: Issued | 01/09/2020 | $11,934.00 | 02/27/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Pentair Water Filtration Company located at 220 Park Dr., Chardon, OH 44024: On or about August 19, 2019, the employer did not ensure that all the steps outlined in 29 CFR 1910.147(d) and required for the control of the hazardous energy sources such as, but not limited to, gravity were followed before employees conducted activities such as, but not limited to, removing jammed plastic material from the rotor blades/knives of the company's (RotoGran) granulating machinery. Employees were exposed to amputation hazards.