Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1419279.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,501.00
Current Penalty: $7,501.00
Issuance Date: 01/10/2020
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 01/29/2020
Gravity: 5
Report ID: 0524700
Contest Date: 02/05/2020
Final Order: 01/17/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 01/17/2022 | $7,501.00 | 01/29/2020 | Serious | |
| Penalty | C: Contested | 02/05/2020 | $7,501.00 | 01/29/2020 | Serious | |
| Penalty | Z: Issued | 01/10/2020 | $7,501.00 | 01/29/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Nox US, LLC - Fostoria, Ohio: On or about October 16, 2019, a projecting shaft end in the Lamination Line 1 pit, located on an ink roller below the pink compression roller, exposed employees to caught-by hazards in that the rotating part was not guarded.