Violation Detail
Standard Cited: 19260502 B03 Fall protection systems criteria and practices.
Inspection Nr: 1417091.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,260.00
Current Penalty: $13,260.00
Issuance Date: 11/12/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 12/17/2019
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 11/12/2019 | $13,260.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge. a. On or about July 22, 2019, at the above addressed jobsite, an employee performing spray foam insulation operations was exposed to a fall of twenty-one (21) feet, while hoisting the hose from the 4th floor balcony opening, due to the failure of the guardrail system. The top rail consisted of a 1" X 6" piece of wood.