Violation Detail
Standard Cited: 19170151 B07 Machine guarding.
Inspection Nr: 1405554.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,956.00
Current Penalty: $5,967.00
Issuance Date: 10/04/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/21/2019
Gravity: 5
Report ID: 0627100
Contest Date:
Final Order: 10/30/2019
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/30/2019 | $5,967.00 | 10/21/2019 | Serious | |
| Penalty | Z: Issued | 10/04/2019 | $7,956.00 | 10/21/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1917.151(b)(7): The power supply to machines was not turned off, locked out and tagged out during repair, adjustment, or servicing: On or about June 3, 2019 and times prior, the employer did not ensure employees performing servicing and maintenance turned off, locked out and tagged out equipment such as but not limited to the following: a. The belt of the auger motor on the north side of the new blenders. b. The east side of the auger on the old blenders.
Translate