Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1403740.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,381.00
Current Penalty: $1,690.00
Issuance Date: 07/19/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/31/2019
Gravity: 1
Report ID: 1032500
Contest Date:
Final Order: 09/17/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/17/2019 | $1,690.00 | 07/31/2019 | Serious | |
| Penalty | Z: Issued | 07/19/2019 | $3,381.00 | 07/31/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Heritage Independent Living- Basement Shop: On or about May 21, 2019 and at times prior: The Curtis Industries Key Cutter (serial no 42346) did not have a guard over the pulley.