Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1399034.015
Citation: 01003
Citation Type: Serious
Abatement Date: 02/03/2020 2
Initial Penalty: $2,842.00
Current Penalty: $1,421.00
Issuance Date: 10/28/2019
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC):
Gravity: 5
Report ID: 0111400
Contest Date:
Final Order: 11/20/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/20/2019 | $1,421.00 | 02/03/2020 | Serious | |
Penalty | Z: Issued | 10/28/2019 | $2,842.00 | 12/18/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Location: Production floor Employees are exposed to electrical shock hazards and crushing hazards while performing maintenance and repairing the Yukon II Bridge Saw, Fastback Polisher and Hydroclear equipment, where a lock out tag out program that included energy control procedures, employee training and periodic inspections was not established or implemented.