Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1396929.015
Citation: 01003
Citation Type: Serious
Abatement Date: 06/20/2019 2
Initial Penalty: $3,978.00
Current Penalty: $2,386.80
Issuance Date: 05/24/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 06/24/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/24/2019 | $2,386.80 | 06/20/2019 | Serious | |
Penalty | Z: Issued | 05/24/2019 | $3,978.00 | 06/20/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) Employees at the site were exposed to fall hazards when a ladder was not installed causing employees to climb the cross braces from the 4th level of the scaffold assemble.