Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1378704.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $8,000.00
Issuance Date: 08/06/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/30/2019
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 08/19/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/19/2019 | $8,000.00 | 09/30/2019 | Serious | |
| Penalty | Z: Issued | 08/06/2019 | $13,260.00 | 08/29/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about 2/19/2019, an employee performed servicing and maintenance activities on machines and equipment such as, but not limited to the Cincinnati press brake, S/N 45136. The employee performing maintenance was not provided lockout or tagout devices to isolate energy sources, inspections on lockout procedures were not performed, nor was training provided to employees on the energy control measures.