Violation Detail
Standard Cited: 19100023 C10 Ladders.
Inspection Nr: 1378700.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,819.00
Current Penalty: $3,409.50
Issuance Date: 07/11/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0419700
Contest Date:
Final Order: 08/01/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/01/2019 | $3,409.50 | Serious | ||
| Penalty | Z: Issued | 07/11/2019 | $6,819.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.23(c)(10): The top of a non-self-supporting ladder is placed so that both side rails are supported, unless the ladder is equipped with a single support attachment: a. On or about February 14, 2019, employees were using one side of an 20-foot extension ladder that was not supported by the ladder rails to gain access to the magnet area to clean out materials and were being exposed to fall hazards.