Violation Detail
Standard Cited: 19100179 B05 Overhead and gantry cranes.
Inspection Nr: 1334039.015
Citation: 01003
Citation Type: Other
Abatement Date: 02/21/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/25/2019
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity:
Report ID: 0420600
Contest Date:
Final Order: 02/19/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 01/25/2019 | $0.00 | 02/21/2019 | Other |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.179(b)(5): Crane(s) with more than one hoisting unit did not have the rated load marked on each hoisting unit or load block: a) At the motor repair and rewinding shops, the structural beams that held hand and electric floor-operated chain hoists did not have the rated load marking. As observed on or about 07/31/2018.