Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1309302.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,114.00
Current Penalty: $4,268.40
Issuance Date: 09/12/2018
Nr Instances: 2
Nr Exposed: 17
Abatement Date: 10/17/2018
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 10/02/2018
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/02/2018 | $4,268.40 | 10/17/2018 | Serious | |
Penalty | Z: Issued | 09/12/2018 | $7,114.00 | 10/17/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: a. On or before April 17, 2018, the employer failed to ensure that employees who service and/or perform maintenance activities including changing blades on the Hyd Mech (model: M-20A; S/N: T1008678) horizontal bandsaw were trained in the purpose and function of the energy control procedure and in the knowledge and skills required for the safe application, usage, and removal of the energy controls. b. On or before April 17, 2018, the employer did not ensure that each affected employee was instructed in the purpose and use of the energy control procedure.