Violation Detail
Standard Cited: 19260451 G01 VII General requirements.
Inspection Nr: 1295207.015
Citation: 01003
Citation Type: Serious
Abatement Date: 08/14/2018 2
Initial Penalty: $3,880.00
Current Penalty: $2,950.00
Issuance Date: 08/08/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A;I
Gravity: 10
Report ID: 0215000
Contest Date: 08/31/2018
Final Order: 01/30/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/30/2019 | $2,950.00 | 08/14/2018 | Serious | |
Penalty | C: Contested | 09/05/2018 | $3,880.00 | 08/14/2018 | Serious | |
Penalty | Z: Issued | 08/08/2018 | $3,880.00 | 08/14/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Courtyard at the end of building abutting the next door building: On or about February 13, 2018 A wood pole scaffold was used to gain access to the area of the roof scupper which was in need of repair. The scaffold did not have a guardrail system in compliance with paragraph (g)(4) of this section nor did the employee wear a personal fall arrest system. The employee worked approximately 35 feet above the ground.