Violation Detail
Standard Cited: 19260451 G01 VII General requirements.
Inspection Nr: 1292022.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $3,880.00
Current Penalty: $3,880.00
Issuance Date: 02/21/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0418200
Contest Date:
Final Order: 03/22/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/21/2018 | $3,880.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: (a) Encore Walk Townhomes, Lot #11 rear side: On or about 02/01/2018, and at times prior, the employer exposed employees to fall hazards while working from a scaffold plank, in that a fall protection system was not provided to employee installing cornice boards on the rear eave.