Violation Detail
Standard Cited: 19100261 L02 Pulp, paper, and paperboard mills.
Inspection Nr: 1264402.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,675.00
Current Penalty: $9,597.00
Issuance Date: 10/20/2017
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 12/08/2017
Gravity: 10
Report ID: 0112600
Contest Date:
Final Order: 11/07/2017
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/07/2017 | $9,597.00 | 12/08/2017 | Serious | |
Penalty | Z: Issued | 10/20/2017 | $12,675.00 | 12/08/2017 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.261(l)(2): Emergency stops. Electrically or manually operated quick power disconnecting devices, interlocked with braking action, shall be provided on all operating sides of the machine within easy reach of all employees. These devices shall be tested by making use of them when stopping the machine. Machine 1 winder, Seaman Paper, 51 Main St., Otter River, Massachusetts; On and before September 28, 2017 the winder for machine 1 was operated with only a single emergency stop switch located at the control panel. The machine has multiple operators and some are not visible from the control station during operation and far out of reach of the emergency stop switch.