Violation Detail
Standard Cited: 19100107 G05 Spray finishing using flammable and combustible materials.
Inspection Nr: 1251555.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,174.00
Current Penalty: $1,200.00
Issuance Date: 01/08/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 02/02/2018
Gravity: 10
Report ID: 0524530
Contest Date: 02/02/2018
Final Order: 02/11/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/11/2019 | $1,200.00 | 02/02/2018 | Serious | |
Penalty | C: Contested | 02/06/2018 | $5,174.00 | 02/02/2018 | Serious | |
Penalty | Z: Issued | 01/08/2018 | $5,174.00 | 02/02/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.107(g)(5): The use of solvents for cleaning operations was not restricted to those having flashpoints not less than 100 degrees Farhrenheit: The employer did not ensure that solvents used to prepare and clean the horizontal support beams for painting had a flashpoint of 100 degrees Fahrenheit or greater. The employer permitted employees to use gasoline as a cleaning solvent.