Violation Detail
Standard Cited: 19100147 F03 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1235535.015
Citation: 01003
Citation Type: Serious
Abatement Date: 10/31/2017 2
Initial Penalty: $9,959.00
Current Penalty: $0.00
Issuance Date: 10/04/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 11/02/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/02/2017 | $0.00 | 10/31/2017 | Serious | |
Penalty | Z: Issued | 10/04/2017 | $9,959.00 | 10/31/2017 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(f)(3)(ii): Group lockout or tagout devices were not used in accordance with procedures required by 29 CFR 1910.147(c)(4): (a) Yard 32 - On or about May 25, 2017, the employer did not ensure that each authorized employee affixed a personal locking device on the battery when working as a group to service the McNeilus Bridgemaster Ready Mix Truck serial # 82755-31060. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.