Violation Detail
Standard Cited: 19100138 A Hand Protection.
Inspection Nr: 1235102.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,243.00
Current Penalty: $3,500.00
Issuance Date: 06/20/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 07/14/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/14/2017 | $3,500.00 | Serious | ||
Penalty | Z: Issued | 06/20/2017 | $7,243.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.138(a): Employers did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances, severe cuts or lacerations, severe abrasions, punctures, chemical burns, thermal burns, and harmful temperature extremes: At 687 Fee Fee Road, Maryland Heights, MO, specifically inside of the Maintenance Department, employee(s) manually poured water into battery cells used to power fork trucks to include, but not limited to, the Yale Fork Truck, m/n ERP030TGN36TE082, s/n E807N04109Z. Employee(s) were provided with MICROFLEX Diamond Grip Powder-Free Latex Gloves, MF-300-XL. This type of glove is not suitable to protect against acid burns. This violation was observed on 05/25/17.