Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 1234806.015
Citation: 01003
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $1,500.00
Issuance Date: 09/22/2017
Nr Instances: 3
Nr Exposed: 40
Abatement Date: 10/04/2017
Gravity:
Report ID: 0523400
Contest Date: 10/17/2017
Final Order: 03/09/2018
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 03/09/2018 | $1,500.00 | 10/04/2017 | Other | |
| Penalty | C: Contested | 10/19/2017 | $0.00 | 10/04/2017 | Serious | |
| Penalty | Z: Issued | 09/22/2017 | $0.00 | 10/04/2017 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.179(j)(2): Frequent inspections of the cranes were not performed at intervals as generally defined in paragraph (j)(1)(ii)(a) of this section or as specifically indicated: (a) The employer was not conducting frequent inspections on overhead cranes to identify hazards associated with crane equipment such as but not limited to pendant control labeling and pendant control cable strain relief.
Translate