Violation Detail
Standard Cited: 19100176 B Handling materials - general.
Inspection Nr: 1226755.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $12,675.00
Current Penalty: $7,605.00
Issuance Date: 07/25/2017
Nr Instances: 1
Nr Exposed: 20
Related Event Code (REC): C
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 08/21/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/21/2017 | $7,605.00 | Serious | ||
Penalty | Z: Issued | 07/25/2017 | $12,675.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: On or about 4/20/2017 in the G-Dock facility at 4300 Plesantdale Road Atlanta, GA: Employees operating powered industrial trucks, picking, and storing pallets of products on the racks are exposed to a struck-by hazard from the unstable and unsecured products being stored on the racks.