Violation Detail
Standard Cited: 19260452 C02 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1225377.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,716.00
Current Penalty: $2,444.40
Issuance Date: 10/05/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/12/2017
Gravity: 5
Report ID: 0214700
Contest Date:
Final Order: 11/02/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/02/2017 | $2,444.40 | 10/12/2017 | Serious | |
| Penalty | Z: Issued | 10/05/2017 | $2,716.00 | 10/12/2017 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.452(c)(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally, and the cross braces were not of such length as would automatically square. a) Worksite- 10 Pleasant Lane, Oyster Bay, NY- Employees were working from a three level, 15'3" scaffold installing brick veneer to the exterior of a residence. The vertical members of the scaffold were not secured. Only one side of the scaffold had crossbracing. There was no crossbracing installed on the sideclosest to the exterior wall; on or about 4/13/17. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.