Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1215150.015
Citation: 01003
Citation Type: Serious
Abatement Date: 09/01/2017 2
Initial Penalty: $12,675.00
Current Penalty: $12,675.00
Issuance Date: 08/24/2017
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC): A
Gravity: 10
Report ID: 0316100
Contest Date:
Final Order: 09/21/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 08/24/2017 | $12,675.00 | 09/01/2017 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) On or about February 28, 2017; south side, employees working in an excavation with vertical walls that were up to 20 feet deep were not protected from cave-in through the use of a support/protective system. b) On or about February 28, 2017; south side, employees working in a trench with vertical walls that exceeded 5-feet deep, were not sloped or protected by a support/protective system. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.