Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1189453.015
Citation: 01003
Citation Type: Serious
Abatement Date: 02/24/2017 2
Initial Penalty: $8,149.00
Current Penalty: $4,074.50
Issuance Date: 02/13/2017
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC): A
Gravity: 5
Report ID: 0729700
Contest Date:
Final Order: 03/02/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/02/2017 | $4,074.50 | 02/24/2017 | Serious | |
Penalty | Z: Issued | 02/13/2017 | $8,149.00 | 02/24/2017 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Employees performing servicing and maintenance activities on equipment, including but not limited to the D-2 cyclone, were exposed to amputation hazards in that an annual inspection was not conducted to ensure that the machine specific procedures were accurate and were being fully implemented.