Violation Detail
Standard Cited: 19260451 B01 I General requirements.
Inspection Nr: 1178451.015
Citation: 01003
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $3,920.00
Current Penalty: $3,920.00
Issuance Date: 12/16/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/22/2016
Gravity: 5
Report ID: 0213400
Contest Date:
Final Order: 02/15/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 12/16/2016 | $3,920.00 | 12/22/2016 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a) 3525 Victory Blvd, Staten Island, NY: The top working level of the fabricated metal frame scaffold where employees were performing masonry work was not fully planked or decked. This hazard was observed on 9/16/16.