Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1150890.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,471.00
Current Penalty: $8,729.70
Issuance Date: 09/19/2016
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 09/23/2016
Gravity: 10
Report ID: 0317000
Contest Date:
Final Order: 10/27/2016
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/27/2016 | $8,729.70 | 09/23/2016 | Serious | |
Penalty | Z: Issued | 09/19/2016 | $12,471.00 | 09/23/2016 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) Jobsite - The employer did not ensure that employees performing servicing and maintenance in a non-routine manner on a Chicago Edge Ultra Maxx Laundry Feeder were protected from an unexpected startup before entering the machine by utilizing locks, blocks, or similar devices. Observed on or about 18 APR 2016.