Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1150890.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,471.00
Current Penalty: $8,729.70
Issuance Date: 09/19/2016
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 09/23/2016
Gravity: 10
Report ID: 0317000
Contest Date:
Final Order: 10/27/2016
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/27/2016 | $8,729.70 | 09/23/2016 | Serious | |
| Penalty | Z: Issued | 09/19/2016 | $12,471.00 | 09/23/2016 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) Jobsite - The employer did not ensure that employees performing servicing and maintenance in a non-routine manner on a Chicago Edge Ultra Maxx Laundry Feeder were protected from an unexpected startup before entering the machine by utilizing locks, blocks, or similar devices. Observed on or about 18 APR 2016.
Translate