Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1140518.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $2,000.00
Issuance Date: 06/29/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/19/2016
Gravity: 5
Report ID: 0728900
Contest Date:
Final Order: 07/21/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/21/2016 | $2,000.00 | 07/19/2016 | Serious | |
| Penalty | Z: Issued | 06/29/2016 | $5,000.00 | 07/19/2016 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section: The employer is failing to protect employees from struck-by and caught-in hazards while servicing the Imabe Iberica H-60/1800 baler. This most recently occurred on April 14, 2016 and date prior below the sorting conveyor located at 440 J Street Lincoln, NE 68508. Machine specific lockout/tagout procedures have not developed for the baler to explain the proper sequence and specific energy isolation points for multiple energy sources such as the conveyor dropping materials into the top of the baler, and specific points to isolate the 480 volt electrical feed and hydraulics.
Translate