Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1120898.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,000.00
Current Penalty: $2,000.00
Issuance Date: 03/16/2016
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0418200
Contest Date:
Final Order: 06/06/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 03/16/2016 | $2,000.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: (a) West side, new residential home located at 3528 Strath Drive, Alpharetta, GA 30005: Employees were not provided with a safe means of access to the work platform. Employees used the ladder jack support ladders to access the working level and the lower level and were exposed to falls of approximately 19-feet, 4-inches to the ground below.