Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1096950.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,300.00
Current Penalty: $4,410.00
Issuance Date: 12/22/2015
Nr Instances: 2
Nr Exposed: 80
Abatement Date: 02/13/2017
Gravity: 10
Report ID: 0524700
Contest Date: 01/15/2016
Final Order: 01/20/2017
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/20/2017 | $4,410.00 | 02/13/2017 | Serious | |
Penalty | C: Contested | 01/20/2016 | $6,300.00 | 02/09/2016 | Serious | |
Penalty | Z: Issued | 12/22/2015 | $6,300.00 | 02/09/2016 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) On or about October 6, 2015, the employer did not ensure that employees isolated the electrical, gravitational and pneumatic energy sources when performing die changes on the Minster 7 mechanical power presses. Employees were exposed to crushing hazards while performing this operation. b) On or about October 6, 2015, the employer did not ensure that employees isolated the electrical and pneumatic energy sources when performing tooling changes on the screw and chucker machines. Employees were exposed to caught in hazards from the rotating parts while performing this operation.