Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 109616.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,060.00
Current Penalty: $2,142.00
Issuance Date: 01/26/2012
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/16/2012
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 02/14/2012
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/14/2012 | $2,142.00 | 02/16/2012 | Serious | |
Penalty | Z: Issued | 01/26/2012 | $3,060.00 | 02/16/2012 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.179(j)(2): The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard: (a) The overhead cranes were inspected on a quarterly basis exposing employees to struck by hazards from inspections not being performed frequently enough.