Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1081204.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,930.00
Current Penalty: $4,500.00
Issuance Date: 01/27/2016
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 02/08/2016
Gravity: 10
Report ID: 0418600
Contest Date:
Final Order: 02/18/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/18/2016 | $4,500.00 | 02/08/2016 | Serious | |
Penalty | Z: Issued | 01/27/2016 | $6,930.00 | 02/08/2016 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Robotic Cell (UMA Line); On or about July 29, 2015 and at times prior; the employer exposed employees to potential hazardous energies in that employees were allowed to service and perform preventive maintenance following a procedure that had not been reviewed at least annually to correct any deviations or inadequacies identified. b) Robotic Cell (ANA Line); On or about July 29, 2015 and at times prior; the employer exposed employees to potential hazardous energies in that employees were allowed to service and perform preventive maintenance following a procedure that had not been reviewed at least annually to correct any deviations or inadequacies identified.