Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1050448.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $1,600.00
Current Penalty: $1,600.00
Issuance Date: 06/19/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 07/17/2015
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 06/19/2015 | $1,600.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Roof Area by Front Porch: Employees used an aluminum extension ladder to access the roof a residence under construction. The ladder was not extended at least 3 feet above the roof landing. The extension ladder was extended 1 and 1/2 feet above the roof, as observed on April 1, 2015.