Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1037687.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 07/31/2015
Nr Instances: 5
Nr Exposed: 5
Abatement Date: 10/02/2015
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 08/25/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/25/2015 | $7,000.00 | 10/02/2015 | Serious | |
Penalty | Z: Issued | 07/31/2015 | $7,000.00 | 08/28/2015 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices are not affixed to each energy isolating device by authorized employees: (a) Welding area; Lockout or tagout devices were not applied to isolate all energy sources while the machine operators and setup personnel performed cleaning and servicing tasks on welders such as, but not limited to: (i) The Fanic Robotic Welder #PL301, (ii) The OTC Welding Robot#PL302, (iii) The ArcWorld by Motoman 100 welding robot #PL303, (iv) The High Weld spot welder #PL350, and (v) The T.J. Snow spot welder #PL351.