Violation Detail
Standard Cited: 19100261 A03 IX Pulp, paper, and paperboard mills.
Inspection Nr: 1020528.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 07/22/2015
Nr Instances: 6
Nr Exposed: 17
Abatement Date: 07/29/2015
Gravity: 10
Report ID: 0213100
Contest Date: 08/05/2015
Final Order: 07/14/2016
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/14/2016 | $7,000.00 | 07/29/2015 | Serious | |
Penalty | C: Contested | 09/24/2015 | $7,000.00 | 07/29/2015 | Serious | |
Penalty | Z: Issued | 07/22/2015 | $7,000.00 | 07/29/2015 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.261(a)(3)(ix): Installation of blower and exhaust systems for dust, stock, and vapor removal or conveying was not in accordance with American Standards Association Z33.1 - 1961 (National Fire Protection Association 91), which is incorporated by reference as specified in 29 CFR 1910.6: a) Cyclone Room Paper Dust Collection System - On or about March 24, 2015, the green cyclone containing combustible paper dust did not have deflagration hazard management. b) Cyclone Room Paper Dust Collection System - On or about March 24, 2015, the amber cyclone containing combustible paper dust did not have deflagration hazard management. c) Cyclone Room Paper Dust Collection System - On or about March 24, 2015,the red cyclone containing combustible paper dust did not have deflagration hazard management.