Violation Detail
Standard Cited: 19260451 F06 General requirements.
Inspection Nr: 1008621.015
Citation: 01003
Citation Type: Willful
Abatement Status: Not Completed - Employer Out of Business
Initial Penalty: $60,500.00
Current Penalty: $48,400.00
Issuance Date: 05/07/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/13/2015
Gravity: 5
Report ID: 0317000
Contest Date: 05/14/2015
Final Order: 05/02/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 05/02/2016 | $48,400.00 | 05/13/2015 | Willful | |
Penalty | C: Contested | 05/29/2015 | $60,500.00 | 05/13/2015 | Willful | |
Penalty | Z: Issued | 05/07/2015 | $60,500.00 | 05/13/2015 | Willful |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(f)(6): Scaffolds are erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6): a) The employer does not ensure that scaffolding is erected at the minimum distances set forth by this OSHA standard. This violation was most recently observed on the property 2028 Federal Street, Philadelphia, PA on 07 NOVEMBER 2014 where employees were applying a brick veneer from the tubular welded frame scaffold less than 3 feet from a single phase power line of approximately 120/240 Volts to ground, exposing employees to a shock and/or electrocution hazard. To abate this ongoing violation the employer must ensure that the power lines are de-energized, rerouted, jumped, or, that the scaffolding is erected at least 10 feet from the energized electrical lines. McGee Plastering and Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(f)(6), which was contained in OSHA inspection number 965324, citation number 1, item number 1 and was affirmed as a final order on June 20, 2014 with respect to a workplace located at 1806 West Montgomery Avenue, Philadelphia, PA. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.451(f)(6), which was contained in OSHA inspection number 314230194, citation number 1, item number 2 and was affirmed as a final order on January 25, 2011 with respect to a workplace located at 200 George Street in Philadelphia, PA. McGee Plastering and Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.416(a)(1), which was contained in OSHA inspection number 314236027, citation number 1, item number 2a and was affirmed as a final order on October 19, 2011 with respect to a workplace located at 1917 Mount Vernon Street, Philadelphia, PA.