Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1203303.015
Citation: 01002F
Citation Type: Serious
Abatement Date: 06/16/2017 2
Initial Penalty: $3,802.00
Current Penalty: $0.00
Issuance Date: 05/04/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 1
Report ID: 0729300
Contest Date:
Final Order: 05/24/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/24/2017 | $0.00 | 06/16/2017 | Serious | |
Penalty | Z: Issued | 05/04/2017 | $3,802.00 | 06/16/2017 | Serious |
Text For Citation: 01 Item/Group: 002F Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: The employer is not requiring lockout/tagout of machines by machine operators authorized to perform repair and maintenance work, such as but not limited to, when replacing pins, changing screens, and replacing squeegees on printers. Work required entering machine areas where moving parts were protected by guard doors, and where alternative safeguards were in need of repair, such as loose emergency stops, and did not always function, such as damaged guard door safety interlocks. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).