Violation Detail
Standard Cited: 19100134 G01 I A Respiratory Protection.
Inspection Nr: 1649408.015
Citation: 01002E
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/30/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/27/2023
Gravity: 1
Report ID: 0830400
Contest Date:
Final Order: 07/20/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/20/2023 | $0.00 | 07/27/2023 | Serious | |
| Penalty | Z: Issued | 06/30/2023 | $0.00 | 07/27/2023 | Serious |
Text For Citation: 01 Item/Group: 002E Hazard:
29 CFR 1910.134(g)(1)(i)(A): Tight-fitting facepieces shall not be worn by employees who have facial hair that comes between the sealing surface of the facepiece and the face: (a)Dakota Digital Inc. at 4510 West 61st Street North, Sioux Falls, SD 57107: On or about and at times prior to February 9, 2023, the employer did not ensure that employees were protected from respiratory injury or illness in that the employer did not prohibit a tight-fitting facepiece to be worn by employees who had facial hair that comes between the sealing surface of the facepiece and the face. This exposed employees to hazards associated with loose or ill fitting protective respiratory equipment.