Violation Detail
Standard Cited: 19100146 D09 Permit-required confined spaces
Inspection Nr: 1602901.015
Citation: 01002E
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/12/2022
Nr Instances: 2
Nr Exposed: 4
Abatement Date: 01/29/2024
Gravity: 10
Report ID: 0213100
Contest Date: 01/10/2023
Final Order: 01/29/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | D: Govt Dismissed | 01/29/2024 | $0.00 | 01/29/2024 | Serious | |
Penalty | C: Contested | 01/10/2023 | $0.00 | 12/30/2022 | Serious | |
Penalty | Z: Issued | 12/12/2022 | $0.00 | 12/30/2022 | Serious |
Text For Citation: 01 Item/Group: 002E Hazard:
29 CFR 1910.146(d)(9): The employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and/or for preventing unauthorized entry. (a) At the worksite (White Lake Facility): On or about��6/19/22, where an employee removed and replaced the Goulds WS0511B submersible sewage pump(s)�in floor drain sump pit(s) in the Kettle Room and Raw Processing Room; no procedures for emergency rescue or preventing unauthorized entry were used. (b) At the worksite (White Lake Facility): On or about 6/12/22, where an employee removed and replaced the Goulds WS0511B submersible sewage pump in floor drain sump pit in the Raw Processing Room; no procedures for emergency rescue or preventing unauthorized entry were used.