Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1797004.015
Citation: 01002D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/02/2025
Nr Instances: 1
Nr Exposed: 50
Abatement Date: 08/29/2025
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 04/22/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/22/2025 | $0.00 | 08/29/2025 | Serious | |
Penalty | Z: Issued | 04/02/2025 | $0.00 | 04/16/2025 | Serious |
Text For Citation: 01 Item/Group: 002D Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) Processing room; On or about January 8, 2025, and days prior, energy control application steps such as, machine shutdown [(d)(2)], machine isolation [(d)(3)], and lockout/tagout device application [(d)(4)] were not in place prior to performing covered activities such as but not limited to clearing jams, replacing plastic rolls, and disassembly/cleanup on the Multivac Type R105 (Serial No. 308042) and the Multivac Type R105 (Serial No. 162229) packaging machines.