Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1745412.015
Citation: 01002D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/05/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 10/03/2024
Gravity: 10
Report ID: 0418600
Contest Date:
Final Order: 10/30/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/30/2024 | $0.00 | 10/03/2024 | Serious | |
Penalty | Z: Issued | 09/05/2024 | $0.00 | 10/03/2024 | Serious |
Text For Citation: 01 Item/Group: 002D Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Manual cutting and polishing area; On or about May 1, 2024: the employer exposed employees to respiratory hazards in that employees were required to wear a tight-fitting negative pressure and N95 respirators without first being fit tested.