Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1705289.015
Citation: 01002D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $0.00
Issuance Date: 01/29/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/16/2024
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/07/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/07/2024 | $0.00 | 02/16/2024 | Serious | |
| Penalty | Z: Issued | 01/29/2024 | $11,292.00 | 02/16/2024 | Serious |
Text For Citation: 01 Item/Group: 002D Hazard:
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section. a) On or about December 6, 2023, the employer did not ensure that the scrap belt on the Newman Trim Saw was fully enclosed to prevent employee contact, exposing employees to caught in hazards.