Violation Detail
Standard Cited: 19100146 D13 Permit-required confined spaces
Inspection Nr: 1694245.015
Citation: 01002D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,063.00
Current Penalty: $0.00
Issuance Date: 01/10/2024
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 02/06/2024
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 02/06/2024
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/06/2024 | $0.00 | 02/06/2024 | Serious | |
| Penalty | Z: Issued | 01/10/2024 | $14,063.00 | 02/06/2024 | Serious |
Text For Citation: 01 Item/Group: 002D Hazard:
29 CFR 1910.146(d)(13): The employer did not review entry operations when the employer had reason to believe that the measures taken under the permit space program may not protect employees and revise the program to correct deficiencies found to exist before subsequent entries are authorized: (a) On or about August 23, 2023, and at times prior to, the employer did not review entry operations into dryer C when the employer received complaints from employees about excessive heat. The employer did not investigate the allegations to correct any deficiencies found to protect employees performing future entries.
Translate