Violation Detail
Standard Cited: 19100146 D06 Permit-required confined spaces
Inspection Nr: 1602901.015
Citation: 01002D
Citation Type: Serious
Abatement Date: 01/29/2024 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/12/2022
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0213100
Contest Date: 01/10/2023
Final Order: 01/29/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/29/2024 | $0.00 | 01/29/2024 | Serious | |
Penalty | C: Contested | 01/10/2023 | $0.00 | 12/30/2022 | Serious | |
Penalty | Z: Issued | 12/12/2022 | $0.00 | 12/30/2022 | Serious |
Text For Citation: 01 Item/Group: 002D Hazard:
29 CFR 1910.146(d)(6): The employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations: (a) At the worksite (White Lake Facility): On or about��6/19/22, where an employee removed and replaced the Goulds WS0511B submersible sewage pump(s)�in floor drain sump pit(s) in the Kettle Room and Raw Processing Room; no attendant was provided. (b) At the worksite (White Lake Facility): On or about 6/12/22, where an employee removed and replaced the Goulds WS0511B submersible sewage pump in floor drain sump pit in the Raw Processing Room; no attendant was provided.