Violation Detail
Standard Cited: 19100147 F03 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1463672.015
Citation: 01002D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,747.00
Current Penalty: $0.00
Issuance Date: 03/19/2020
Nr Instances: 8
Nr Exposed: 10
Abatement Date: 06/30/2020
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 04/16/2020
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/16/2020 | $0.00 | 06/30/2020 | Serious | |
Penalty | Z: Issued | 03/19/2020 | $6,747.00 | 04/16/2020 | Serious |
Text For Citation: 01 Item/Group: 002D Hazard:
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance is performed by a crew, craft, department or other group, they shall utilize a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device. On 2 Press (PCMC, S/N: 6983) each authorized employee was not afforded a level of protection equivalent to a personal lockout device. The helper, during the miking activity, did not have control over the jog pendant exposing the employee to unexpected startup of the equipment. On 6 Press (PCMC, S/N: 6652) each authorized employee was not afforded a level of protection equivalent to a personal lockout device. The helper, during the miking activity, did not have control over the jog pendant exposing the employee to unexpected startup of the equipment.