Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 907878.015
Citation: 01002C
Citation Type: Serious
Abatement Date: 08/01/2013 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/12/2013
Nr Instances: 1
Nr Exposed: 40
Related Event Code (REC):
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 08/02/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/02/2013 | $0.00 | 08/01/2013 | Serious | |
Penalty | Z: Issued | 07/12/2013 | $0.00 | 08/01/2013 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded rotating shaft ends projected more than one-half the diameter of the shaft: a) On or about June 24, 2013 the rotating shaft protruding from the line transfer conveyor near the diverter was not guarded when the protrusion exceeded one-half the diameter of the shaft. Abatement Certification and Abatement Documentation Required.