Violation Detail
Standard Cited: 19100119 E03 IV Process safety management of highly hazardous chemicals.
Inspection Nr: 314464900
Citation: 01002C
Citation Type: Serious
Abatement Status: X
Initial Penalty:
Current Penalty:
Issuance Date: 09/30/2010
Nr Instances: 1
Nr Exposed: 900
Abatement Date: 05/02/2011
Gravity: 02
Report ID: 0728500
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/19/2010 | 05/02/2011 | Serious | ||
| Penalty | Z: Issued | 09/30/2010 | 11/02/2010 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard: CHEMNEP
29 CFR 1910.119(e)(3)(iv): The process hazard analysis did not address the consequences of failure of engineering and administrative controls: The PHA did not address the consequences of the failure of engineering and administrative controls such as, but not limited to, failure of a mechanical integrity program, failure of a preventative maintenance program, failure of incident investigations, failure of Management of Change procedures and failure of an effective emergency response program. Abatement Note: Abatement certification is required for this item using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET.