Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1826616.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/09/2025
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 09/29/2025
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 07/07/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 07/30/2025 | $0.00 | 09/29/2025 | Serious | |
Penalty | I: Informal Settlement | 07/07/2025 | $0.00 | 06/24/2025 | Serious | |
Penalty | Z: Issued | 06/09/2025 | $0.00 | 06/24/2025 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) South plant make room; On or about May 19, 2025, the local disconnect for the west filler auger was not isolated prior to clearing a clog in the filler, which resulted in a severe hand injury.