Violation Detail
Standard Cited: 19261204 I
Inspection Nr: 1787385.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/05/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/01/2025
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 04/01/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/01/2025 | $0.00 | 05/01/2025 | Serious | |
| Penalty | Z: Issued | 03/05/2025 | $0.00 | 03/25/2025 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1926.1204(i): (i) Develop and implement procedures for summoning rescue and emergency services (including procedures for summoning emergency assistance in the event of a failed non-entry rescue), for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue; a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to develop and implement procedures for summoning rescue and emergency services, including procedures for non-entry rescue, providing emergency assistance to rescued employees, and preventing unauthorized personnel from attempting a rescue. As a result, employees entered a permit-required confined space without established procedures for responding to an emergency, including how to summon rescue services or conduct a non-entry rescue if needed.